<td id="kg486"><optgroup id="kg486"></optgroup></td>
<button id="kg486"><tbody id="kg486"></tbody></button>
<li id="kg486"><dl id="kg486"></dl></li>
  • <dl id="kg486"></dl>
  • <code id="kg486"><tr id="kg486"></tr></code>

  • IR-TEC International Ltd.

    Taiwan Manufacturers, Exporters.

    Products

    System Master Sensors

    system master sensor

    • Model No: HEM-550
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. HEM-550 is the master sensor of HEM-1 guestroom HVAC energy Management System. This is not only an occupancy sensor, but also
    a signal processor of the system.
    2. With integration of various signals and logic sequence analysis, this sensor is able to verify the actual occupancy status of the room without detecting continued movements of the guest.
    3. When guestroom is physically occupied, the HEM-550 will
    command PP-116 to provide power for HVAC operation. After the guestroom is vacant, the HEM-550 will command PP-116 to shut off the power for HVAC operation to reduce the energy consumption.

    Specification :

    1. Power supply: 24 2 V AC / DC. 2. Detection range: 110, 15 x 15 m at 25C. 3. Relay output: form C, 24V / dry contact selectable. 4. Relay contact AC: 250V, DC: 30V, 5A resistive load. 5. Current drain: Standby: 20 mA, active: 10 mA. 6. High-temp limit 30 / 28 / 26C (85 / 82 / 79F). 7. Low-temp limit 15 / 13 / 11C (59 / 55 / 51F). 8. Mounting height: 1.8 ~ 3.6m. 9. Restart cycle 2 minutes, can be disabled. 10. Test indication Buzzer and LED, can be disabled. 11. Detectable speed 0.1~ 3 m/sec.(0.3~10 ft/sec.). 12. RFI immunity Av. 20 V/m (10~1,000 MHz). 13. Humidity: 95% RH max. 14. Temperature: -10C~60C (14F~140F). 15. Dimensions: 112 x 66 x 45 mm (4.4 x 2.6 x 1.8").

    Features :

    1. High density detection capability.
    2. Selectable relay output format.
    3. High-low temperature setbacks.
    4. 2-minute restart cycle protection.
    5. Audible & visible test indications.
    6. Superior RFI and EMI immunity.
    7. Occupancy status signal output.
    8. Wall / corner / ceiling mount available.
    9. Additional slave sensor connectivity.
    10. 5-minute door open HVAC shut off.

    IR-TEC International Ltd.

    • Taiwan
    主站蜘蛛池模板: 男生和女生一起差差差很痛视频| 丰满少妇又爽又紧又丰满在线观看| a级毛片100部免费观看| 久久91精品国产91久久小草| 龙珠全彩里番acg同人本子 | 一本丁香综合久久久久不卡网站 | 久久精品视频一区| 久久人人做人人玩人精品| 美女免费视频一区二区| 无码A级毛片免费视频内谢| 国产黄三级高清在线观看播放| 亚洲精品视频在线观看视频| 99热这里只有精品99| 波多野结衣被躁| 国产美女做a免费视频软件| 亚洲欧美日韩高清综合678| 三级三级三级网站网址| 精品亚洲视频在线| 女人扒开尿口给男人捅| 亚洲综合色视频在线观看| 91精品国产高清| 樱桃视频高清免费观看在线播放 | 嘟嘟嘟在线视频免费观看高清中文| 中文字幕免费在线观看动作大片 | av一本久道久久综合久久鬼色| 舌头伸进去里面吃小豆豆| 成人五级毛片免费播放| 免费观看国产精品| 99RE66在线观看精品免费| 欧美怡红院高清在线| 在线视频亚洲一区| 亚洲国产精品无码久久一线| 狠狠色欧美亚洲综合色黑a| 日本伊人色综合网| 八区精品色欲人妻综合网| 99精品全国免费观看视频| 欧美国产日本高清不卡| 国产对白在线观看| 中文在线а√天堂| 爽爽影院在线免费观看| 国产精品亚洲欧美云霸高清|