  • IR-TEC International Ltd.

    Taiwan Manufacturers, Exporters.

    Products

    HEM-2 System Master Sensors

    system master sensor

    • Model No: HEM-550E
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. HEM-550E is the master sensor of HEM-2 Guestroom HVAC Energy Management System. This is not only an occupancy sensor, but also a signal processor of the system.
    2. With superior detection capability, this sensor is able to detect the slightest movement of hotel guest.
    3. When guestroom is physically occupied, the HEM-550E will command PP-116 to provide power for HVAC operation.
    4. After the guestroom is vacant, the HEM-550E will command PP-116 to shut off the power for HVAC operation to reduce the energy consumption.

    Specification :

    1. Power supply 24 2 VAC / DC. 2. Detection range: 110, 15 x 15 m at 25C. 3. Relay output: form C, 5A / NO, 3A / NC resistive. 4. Current drain: standby: 7 mA, Active: 23 mA. 5. High-temp limit 30 / 28 / 26C (85 / 82 / 79F). 6. Low-temp limit 15 / 13 / 11C (59 / 55 / 51F). 7. Mounting height: 1.8 ~ 3.6m. 8. ON delay 0 - 10" - 30" - 1' - 5' - 10' selectable. 9. OFF delay 10" - 1' - 5' - 10' - 20' - 30' selectable. 10. Detectable speed 0.1~ 3 m/sec.(0.3~10 ft/sec.). 11. RFI immunity Av. 20 V/m (10~1,000 MHz). 12. Humidity: 95% RH max. 13. Temperature: -10C~60C (14F~140F). 14. Dimensions 112 x 66 x 45 mm (4.4 x 2.6 x 1.8").

    Features :

    1. High density detection capability.
    2. Form C changeover relay output.
    3. High-low temperature setbacks.
    4. Superior RFI and EMI immunity.
    5. Disabled walk test LED indication.
    6. Optional door switch connectivity.
    7. Wall / corner / ceiling mount available.
    8. 5-minute door open HVAC shut off.
    9. Programmable ON & OFF delay times.
    10. Automatic temperature compensation.

    IR-TEC International Ltd.

    • Taiwan
    主站蜘蛛池模板: 成年人视频网址| 欧美日本在线三级视频| 在线国产小视频| 久热中文字幕在线| 老司机午夜在线视频| 国产男女猛视频在线观看| a毛片免费全部在线播放**| 最刺激黄a大片免费观看下截| 国产99视频精品免费视频7| 99久久精品久久久久久清纯| 日韩美香港a一级毛片| 厨房掀起馊子裙子挺进去| 67194老司机精品午夜| 日本人强jizzjizz| 亚洲乱人伦在线| 美女大量吞精在线观看456| 国产女人的一级毛片视频| yy6080一级毛片高清| 樱桃视频影院在线观看| 别揉我胸啊嗯动漫网站| 青青热久久久久综合精品| 成人福利免费视频| 亚洲丁香婷婷综合久久| 精品久久久久久无码中文野结衣| 国产精品亚洲专一区二区三区| 中国少妇无码专区| 欧美一级亚洲一级| 免费无码成人AV片在线在线播放| 免费观看国产网址你懂的| 天美麻花视频大全| 久久综合久久鬼色| 激情小说亚洲色图| 国产亚洲成av人片在线观黄桃| 97精品久久天干天天蜜| 手机在线观看视频你懂的| 亚洲一级毛片免观看| 欧美日韩一区二区三区麻豆| 亚洲精品动漫免费二区| 老司机永久免费视频| 国产精品久久久久久久久电影网 | 久久精品国产一区二区电影|