Description :
Features:
1. Industry standard footprint: 2" x 1" x 0.4" ( 50.80 x 25.40 x 10.16mm3).
2. Typical efficiency: 84%.
3. Wide input voltage: 36 - 75V.
4. Single output: 3.3V, 5V.
5. Remote control.
6. Trim and sense function.
7. Input under-voltage shutdown.
8. Output over-current protection.
9. Output over-voltage protection.
10. Output short-circuit protection.
11. No minimum load requirement.
12. Basic isolation.
Specification :
1. Electrical specifications:
(1) Input range: 36 - 75 Vdc.
(2) Input under-voltage shutdown: 32 - 35 Vdc.
(3) Output voltage setpoint accuracy: ± 1.0% Vo max.
(4) Output voltage adjust: 90% to 110% Vo.
(5) Line regulation: 0.2% Vo max.
(6) Load regulation: 0.5% Vo max.
(7) Short-circuit protection: continuous, auto-recovery ( or latch off).
(8) Over-current protection: > 120% Io, auto-recovery.
(9) Over-voltage protection: > 120% Vo, lamped.
(10) Ripple and noise: < 100 mVpp max.
(11) Transient response: recovery < 200uS max 100mV max. ( 25% step load change from 50% Io).
(12) DI / Dt: 1A / 10uS.
2. Environment:
(1) Operating ambient temperature range: -40℃ to 55℃.
(2) Operating case temperature range: -40℃ to 100℃.
(3) Storage temperature: -55℃ to 125℃.
(4) Temp. coefficient: < ± 0.02%/ ℃.
(5) MTBF: > 2 million hrs.
3. Control.
(1) Positive logic:
High = on: 3.5 to 10Vdc.
Low = off: - 0.7 to 0.8Vdc.
(2) Negtive logic:
Low = on: - 0.7 to 0.8Vdc.
High = off: 3.5 to 10Vdc.
(3) Control current: 2mA max.